{"id":628,"date":"2026-10-15T03:20:55","date_gmt":"2026-10-15T03:20:55","guid":{"rendered":"https:\/\/ctxcooling.com\/?post_type=cxdb_product&#038;p=628"},"modified":"2026-10-15T03:20:55","modified_gmt":"2026-10-15T03:20:55","slug":"cabinet-mounted-air-to-liquid-cdu","status":"publish","type":"cxdb_product","link":"https:\/\/www.ctxcooling.com\/ko\/cooling-products\/cabinet-mounted-air-to-liquid-cdu\/","title":{"rendered":"Cabinet-mounted Air-to-Liquid CDU"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>Designed for high heat density liquid-cooled server applications without an external cooling-water supply.<\/p>","protected":false},"menu_order":5,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_kadence_starter_templates_imported_post":false,"cxdb_product":{"schema_version":1,"group":"liquid","model":"CDU-16AJ \u00b7 CDU-120AL3SS61222","overview":"Cabinet-mounted Air-to-Liquid CDU is designed specifically for high heat density liquid-cooled server application scenarios. It requires no external cooling water supply or overhead cabling via raised floor systems. The overall cooling system layout is simple, with a short installation cycle and easy operation and maintenance. It is particularly suitable for retrofitting traditional air-cooled data centers and small high-performance computing centers.","working_principle":"The cabinet-mounted air-to-liquid CDU consists of rear fans, high-efficiency air-to-liquid heat exchangers, water pumps, controllers and pipeline components. Driven by the water pump, high-temperature working fluid from liquid-cooled servers undergoes convective heat exchange with cold air in the data room. After cooling, the fluid returns to the liquid-cooled servers to complete the heat exchange cycle.","features":["Single-cabinet heat exchange capacity up to 120 kW","Rapid deployment","Two high-performance water pumps","Integrated control system supporting mainstream communication protocols","N+1 high-efficiency hot-swappable fans","Total power consumption below 5% of heat load","Compatible with existing hot and cold aisle layouts"],"applications":[],"notes":["Both model tables appear on slide 5 with the cabinet-mounted air-to-liquid description. They are preserved separately; the source does not explicitly map every cabinet feature to both models.","Cooling capacity depends on working conditions. Confirm the selected working conditions and cooling medium with technical personnel.","CDU-16AJ filtration is 100 \u03bcm; CDU-120AL3SS61222 filtration is 100 mesh. These are different source units and are not interchangeable.","The 120 kW model lists <5 kW consumption; the description separately states total power below 5% of the heat load. These apply to the specified operating point, not every load."],"source":"Liquid Cooling Manual, p. 5","image":{"id":658,"alt":"Cabinet-mounted Air-to-Liquid CDU"},"diagrams":[],"tables":[{"title":"CDU-16AJ model specifications","rows":[["MODEL","CDU-16AJ"],["Heat exchange capacity (kW)","16"],["Primary side inlet air temperature (\u00b0C)","25"],["Air volume (m\u00b3\/h)","2700"],["Secondary side liquid supply temperature (\u00b0C)","40"],["Secondary side working fluid","PG25"],["Secondary side flow rate (L\/min)","25"],["Secondary side filtration precision","100\u03bcm"],["Secondary side connection type","1.5\" tri-clamp"],["Circulating pump quantity","Dual pumps"],["Dimensions W \u00d7 D \u00d7 H (mm)","482*857*443"],["Power supply specifications","220V\/50Hz"]]},{"title":"CDU-120AL3SS61222 model specifications","rows":[["MODEL","CDU-120AL3SS61222"],["Heat exchange capacity (kW)","120"],["Primary air inlet temperature (\u00b0C)","24"],["Airflow rate (m\u00b3\/h)","15000"],["Secondary fluid inlet temperature (\u00b0C)","\u2264 45"],["Secondary filtration precision (mesh)","100"],["Secondary interface size","DN50"],["Circulating pump quantity","2"],["Dimensions W \u00d7 D \u00d7 H (mm)","600*1200*2200"],["Power supply specifications","380V\/50Hz"],["Power consumption (kW)","<5"]]}]}},"class_list":["post-628","cxdb_product","type-cxdb_product","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Cabinet-mounted Air-to-Liquid CDU - Cooltechx<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ctxcooling.com\/ko\/cooling-products\/cabinet-mounted-air-to-liquid-cdu\/\" \/>\n<meta property=\"og:locale\" content=\"ko_KR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Cabinet-mounted Air-to-Liquid CDU - Cooltechx\" \/>\n<meta property=\"og:description\" content=\"Designed for high heat density liquid-cooled server applications without an external cooling-water supply.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ctxcooling.com\/ko\/cooling-products\/cabinet-mounted-air-to-liquid-cdu\/\" \/>\n<meta property=\"og:site_name\" content=\"Cooltechx\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ctxcooling.com\/wp-content\/uploads\/2026\/10\/cxdb-c4d5afc05e433ef830e21474.png\" \/>\n\t<meta property=\"og:image:width\" content=\"303\" \/>\n\t<meta property=\"og:image:height\" content=\"76\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.ctxcooling.com\/wp-content\/uploads\/2026\/10\/cxdb-c4d5afc05e433ef830e21474.png\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/cooling-products\\\/cabinet-mounted-air-to-liquid-cdu\\\/\",\"url\":\"https:\\\/\\\/www.ctxcooling.com\\\/cooling-products\\\/cabinet-mounted-air-to-liquid-cdu\\\/\",\"name\":\"Cabinet-mounted Air-to-Liquid CDU - Cooltechx\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/#website\"},\"datePublished\":\"2026-10-15T03:20:55+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/cooling-products\\\/cabinet-mounted-air-to-liquid-cdu\\\/#breadcrumb\"},\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.ctxcooling.com\\\/cooling-products\\\/cabinet-mounted-air-to-liquid-cdu\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/cooling-products\\\/cabinet-mounted-air-to-liquid-cdu\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Cabinet-mounted Air-to-Liquid CDU\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/#website\",\"url\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/\",\"name\":\"Cooltechx\",\"description\":\"End-to-end data center temperature control: cold-plate liquid cooling and precision air conditioning, factory-built and ready to deploy.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ko-KR\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/#organization\"}},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/#organization\",\"name\":\"Cooltechx\",\"url\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/#organization-logo\",\"url\":\"https:\\\/\\\/www.ctxcooling.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/cxdb-c4d5afc05e433ef830e21474.png\",\"width\":303,\"height\":76,\"caption\":\"Cooltechx\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Cabinet-mounted Air-to-Liquid CDU - Cooltechx","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ctxcooling.com\/ko\/cooling-products\/cabinet-mounted-air-to-liquid-cdu\/","og_locale":"ko_KR","og_type":"article","og_title":"Cabinet-mounted Air-to-Liquid CDU - Cooltechx","og_description":"Designed for high heat density liquid-cooled server applications without an external cooling-water supply.","og_url":"https:\/\/www.ctxcooling.com\/ko\/cooling-products\/cabinet-mounted-air-to-liquid-cdu\/","og_site_name":"Cooltechx","og_image":[{"width":303,"height":76,"url":"https:\/\/www.ctxcooling.com\/wp-content\/uploads\/2026\/10\/cxdb-c4d5afc05e433ef830e21474.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_image":"https:\/\/www.ctxcooling.com\/wp-content\/uploads\/2026\/10\/cxdb-c4d5afc05e433ef830e21474.png","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ctxcooling.com\/cooling-products\/cabinet-mounted-air-to-liquid-cdu\/","url":"https:\/\/www.ctxcooling.com\/cooling-products\/cabinet-mounted-air-to-liquid-cdu\/","name":"Cabinet-mounted Air-to-Liquid CDU - Cooltechx","isPartOf":{"@id":"https:\/\/www.ctxcooling.com\/ko\/#website"},"datePublished":"2026-10-15T03:20:55+00:00","breadcrumb":{"@id":"https:\/\/www.ctxcooling.com\/cooling-products\/cabinet-mounted-air-to-liquid-cdu\/#breadcrumb"},"inLanguage":"ko-KR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ctxcooling.com\/cooling-products\/cabinet-mounted-air-to-liquid-cdu\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ctxcooling.com\/cooling-products\/cabinet-mounted-air-to-liquid-cdu\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ctxcooling.com\/ko\/"},{"@type":"ListItem","position":2,"name":"Cabinet-mounted Air-to-Liquid CDU"}]},{"@type":"WebSite","@id":"https:\/\/www.ctxcooling.com\/ko\/#website","url":"https:\/\/www.ctxcooling.com\/ko\/","name":"Cooltechx","description":"End-to-end data center temperature control: cold-plate liquid cooling and precision air conditioning, factory-built and ready to deploy.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ctxcooling.com\/ko\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ko-KR","publisher":{"@id":"https:\/\/www.ctxcooling.com\/ko\/#organization"}},{"@type":"Organization","@id":"https:\/\/www.ctxcooling.com\/ko\/#organization","name":"Cooltechx","url":"https:\/\/www.ctxcooling.com\/ko\/","logo":{"@type":"ImageObject","@id":"https:\/\/www.ctxcooling.com\/ko\/#organization-logo","url":"https:\/\/www.ctxcooling.com\/wp-content\/uploads\/2026\/10\/cxdb-c4d5afc05e433ef830e21474.png","width":303,"height":76,"caption":"Cooltechx"}}]}},"_links":{"self":[{"href":"https:\/\/www.ctxcooling.com\/ko\/wp-json\/wp\/v2\/cxdb_product\/628","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ctxcooling.com\/ko\/wp-json\/wp\/v2\/cxdb_product"}],"about":[{"href":"https:\/\/www.ctxcooling.com\/ko\/wp-json\/wp\/v2\/types\/cxdb_product"}],"wp:attachment":[{"href":"https:\/\/www.ctxcooling.com\/ko\/wp-json\/wp\/v2\/media?parent=628"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}