{"id":630,"date":"2026-10-15T03:21:04","date_gmt":"2026-10-15T03:21:04","guid":{"rendered":"https:\/\/ctxcooling.com\/?post_type=cxdb_product&#038;p=630"},"modified":"2026-10-15T03:21:04","modified_gmt":"2026-10-15T03:21:04","slug":"liquid-cooling-manifold","status":"publish","type":"cxdb_product","link":"https:\/\/www.ctxcooling.com\/ko\/cooling-products\/liquid-cooling-manifold\/","title":{"rendered":"Manifold"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>A flow distribution device connecting the CDU to cold plates in rack-mounted servers.<\/p>","protected":false},"menu_order":7,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_kadence_starter_templates_imported_post":false,"cxdb_product":{"schema_version":1,"group":"liquid","model":"MF-DS \u00b7 MF-BS","overview":"The manifold is a water distribution and collection header for server liquid cooling, connecting the CDU to the cold plates of rack-mounted servers. It is available in quick-disconnect and blind-mate versions. It can be integrated into or externally connected to the cabinet frame, with branch flow selected according to server heat dissipation requirements.","working_principle":"","features":["304 stainless-steel main body, air vent and related components; EPDM hoses for corrosion resistance.","Pipeline design targets branch-flow non-uniformity below 10%.","Customized for server layout and multiple cabinet mounting methods.","In-cabinet installation operable by one person.","Server branch connectors use drip-free quick connections for installation and maintenance.","Deionized-water rinsing, high-temperature gas drying and transport under 1.5 bar gas pressure for cleanliness."],"applications":[],"notes":["Slide 7 places branch configuration under the printed Material column and material under Number of Branches; the table above uses labels matching the actual cell content. Its printed Working Pressure column contains fluid names; no numeric working pressure is supplied.","The slide 7 model series has standard 16-inlet\/16-outlet configuration; slides 29\u201330 give separate typical engineering guidance of 20 branches. The typical guidance is not a rating for every MF model.","The 30 \u00d7 30 \/ 40 \u00d7 40 \/ 50 \u00d7 50 source table does not print a dimension unit. The 33 \u00d7 33 mm example comes from slide 30."],"source":"Liquid Cooling Manual, pp. 6\u20137 and 29\u201330","image":{"id":660,"alt":"Manifold"},"diagrams":[],"tables":[{"title":"MF-DS \/ MF-BS model matrix","rows":[["Model family","Square-section specification (source notation)","Branch configuration","Material","Connection","Applicable fluid"],["MF-DS*","30 \u00d7 30","Customizable; standard 16 inlet + 16 outlet","SUS304 \/ SUS316L","Quick-disconnect","Ethylene glycol solution, propylene glycol solution, deionized water"],["MF-DS*","40 \u00d7 40","Customizable; standard 16 inlet + 16 outlet","SUS304 \/ SUS316L","Quick-disconnect","Ethylene glycol solution, propylene glycol solution, deionized water"],["MF-DS*","50 \u00d7 50","Customizable; standard 16 inlet + 16 outlet","SUS304 \/ SUS316L","Quick-disconnect","Ethylene glycol solution, propylene glycol solution, deionized water"],["MF-BS*","30 \u00d7 30","Customizable; standard 16 inlet + 16 outlet","SUS304 \/ SUS316L","Blind-mate","Ethylene glycol solution, propylene glycol solution, deionized water"],["MF-BS*","40 \u00d7 40","Customizable; standard 16 inlet + 16 outlet","SUS304 \/ SUS316L","Blind-mate","Ethylene glycol solution, propylene glycol solution, deionized water"],["MF-BS*","50 \u00d7 50","Customizable; standard 16 inlet + 16 outlet","SUS304 \/ SUS316L","Blind-mate","Ethylene glycol solution, propylene glycol solution, deionized water"]]},{"title":"Distribution-unit engineering guidance","rows":[["Parameter","Typical source guidance"],["Server types","Rack-mounted liquid-cooled servers and blade liquid-cooled servers"],["Internal pipework","Stainless steel; sanitary clamp connections"],["Installation","Integrated into or externally connected to the cabinet frame"],["Branch flow","1\u20134 L\/min, based on server heat-dissipation requirements"],["Branch port diameter","Typically 3\u20136 mm, with matched quick connectors"],["Quick connector material","Typically stainless steel or aluminum"],["Example connector brands","Staubli, Parker, CPC"],["Air removal \/ drainage","Automatic air vent and drain"],["Branch regulation","No branch flow or temperature control"],["Typical fabrication","Constant-diameter stainless-steel square tubing"],["Typical branch count","20 branches, supporting 20 servers per cabinet"],["Distribution arrangement","Typically one unit per cabinet; single server inlet and outlet"],["Branch connections","External threads; end caps applied at factory; G1\/8 common according to server interface"],["Mounting","Generally at cabinet rear door, separate from PDU"],["Typical outer dimension","Approximately 33 \u00d7 33 mm"]]}]}},"class_list":["post-630","cxdb_product","type-cxdb_product","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Manifold - Cooltechx<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ctxcooling.com\/ko\/cooling-products\/liquid-cooling-manifold\/\" \/>\n<meta property=\"og:locale\" content=\"ko_KR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Manifold - Cooltechx\" \/>\n<meta property=\"og:description\" content=\"A flow distribution device connecting the CDU to cold plates in rack-mounted servers.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ctxcooling.com\/ko\/cooling-products\/liquid-cooling-manifold\/\" \/>\n<meta property=\"og:site_name\" content=\"Cooltechx\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ctxcooling.com\/wp-content\/uploads\/2026\/10\/cxdb-c4d5afc05e433ef830e21474.png\" \/>\n\t<meta property=\"og:image:width\" content=\"303\" \/>\n\t<meta property=\"og:image:height\" content=\"76\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.ctxcooling.com\/wp-content\/uploads\/2026\/10\/cxdb-c4d5afc05e433ef830e21474.png\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/cooling-products\\\/liquid-cooling-manifold\\\/\",\"url\":\"https:\\\/\\\/www.ctxcooling.com\\\/cooling-products\\\/liquid-cooling-manifold\\\/\",\"name\":\"Manifold - Cooltechx\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/#website\"},\"datePublished\":\"2026-10-15T03:21:04+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/cooling-products\\\/liquid-cooling-manifold\\\/#breadcrumb\"},\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.ctxcooling.com\\\/cooling-products\\\/liquid-cooling-manifold\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/cooling-products\\\/liquid-cooling-manifold\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Manifold\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/#website\",\"url\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/\",\"name\":\"Cooltechx\",\"description\":\"End-to-end data center temperature control: cold-plate liquid cooling and precision air conditioning, factory-built and ready to deploy.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ko-KR\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/#organization\"}},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/#organization\",\"name\":\"Cooltechx\",\"url\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.ctxcooling.com\\\/ko\\\/#organization-logo\",\"url\":\"https:\\\/\\\/www.ctxcooling.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/cxdb-c4d5afc05e433ef830e21474.png\",\"width\":303,\"height\":76,\"caption\":\"Cooltechx\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Manifold - Cooltechx","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ctxcooling.com\/ko\/cooling-products\/liquid-cooling-manifold\/","og_locale":"ko_KR","og_type":"article","og_title":"Manifold - Cooltechx","og_description":"A flow distribution device connecting the CDU to cold plates in rack-mounted servers.","og_url":"https:\/\/www.ctxcooling.com\/ko\/cooling-products\/liquid-cooling-manifold\/","og_site_name":"Cooltechx","og_image":[{"width":303,"height":76,"url":"https:\/\/www.ctxcooling.com\/wp-content\/uploads\/2026\/10\/cxdb-c4d5afc05e433ef830e21474.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_image":"https:\/\/www.ctxcooling.com\/wp-content\/uploads\/2026\/10\/cxdb-c4d5afc05e433ef830e21474.png","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ctxcooling.com\/cooling-products\/liquid-cooling-manifold\/","url":"https:\/\/www.ctxcooling.com\/cooling-products\/liquid-cooling-manifold\/","name":"Manifold - Cooltechx","isPartOf":{"@id":"https:\/\/www.ctxcooling.com\/ko\/#website"},"datePublished":"2026-10-15T03:21:04+00:00","breadcrumb":{"@id":"https:\/\/www.ctxcooling.com\/cooling-products\/liquid-cooling-manifold\/#breadcrumb"},"inLanguage":"ko-KR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ctxcooling.com\/cooling-products\/liquid-cooling-manifold\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ctxcooling.com\/cooling-products\/liquid-cooling-manifold\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ctxcooling.com\/ko\/"},{"@type":"ListItem","position":2,"name":"Manifold"}]},{"@type":"WebSite","@id":"https:\/\/www.ctxcooling.com\/ko\/#website","url":"https:\/\/www.ctxcooling.com\/ko\/","name":"Cooltechx","description":"End-to-end data center temperature control: cold-plate liquid cooling and precision air conditioning, factory-built and ready to deploy.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ctxcooling.com\/ko\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ko-KR","publisher":{"@id":"https:\/\/www.ctxcooling.com\/ko\/#organization"}},{"@type":"Organization","@id":"https:\/\/www.ctxcooling.com\/ko\/#organization","name":"Cooltechx","url":"https:\/\/www.ctxcooling.com\/ko\/","logo":{"@type":"ImageObject","@id":"https:\/\/www.ctxcooling.com\/ko\/#organization-logo","url":"https:\/\/www.ctxcooling.com\/wp-content\/uploads\/2026\/10\/cxdb-c4d5afc05e433ef830e21474.png","width":303,"height":76,"caption":"Cooltechx"}}]}},"_links":{"self":[{"href":"https:\/\/www.ctxcooling.com\/ko\/wp-json\/wp\/v2\/cxdb_product\/630","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ctxcooling.com\/ko\/wp-json\/wp\/v2\/cxdb_product"}],"about":[{"href":"https:\/\/www.ctxcooling.com\/ko\/wp-json\/wp\/v2\/types\/cxdb_product"}],"wp:attachment":[{"href":"https:\/\/www.ctxcooling.com\/ko\/wp-json\/wp\/v2\/media?parent=630"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}