FSA1008F/D · FSA1013F/D · FSA1020F/D
Small-room Precision Air Conditioner
The product uses a full DC inverter compressor, indoor EC speed-regulating fan, electronic expansion valve and condenser fan speed regulation to provide stepless cooling-capacity adjustment and 30% energy saving.
Discuss this productFeatures & technical specifications4 specification tables
Product features
- DC inverter compressor, indoor EC variable-speed fan, electronic expansion valve and variable-speed condenser fan provide stepless cooling capacity control and 30% energy savings.
- Intelligent controls adjust fan speed to cooling demand, substantially reducing fan energy consumption.
- Cooling/heating and constant-temperature-and-humidity configurations meet different application requirements.
- Front top discharge, ducted top discharge and underfloor discharge support different airflow arrangements.
- Components from established brands provide high reliability, a design life exceeding ten years and low maintenance costs.
- A 4.3-inch touchscreen and multiple temperature and pressure sensors display unit operating status for operation and maintenance.
- High airflow and a small enthalpy difference meet equipment-room requirements for a high sensible heat ratio.
- Uses R410A refrigerant.
- Automatically restarts after power restoration and resumes the operating state used before the outage.
- Standard RS485 communication interface; a communication protocol can be supplied.
- Extensive self-diagnostics, alarms and protection functions support safe, reliable operation.
| Parameter | FSA1008F/D (220V) | FSA1008F/D (380V) | FSA1013F/D | FSA1020F/D |
|---|---|---|---|---|
| Cooling capacity (kW) | 7.8 | 7.8 | 13.2 | 20.8 |
| Sensible cooling capacity (kW) | 7.5 | 7.5 | 12.6 | 20 |
| Airflow (m³/h) | 2800 | 2800 | 3200 | 7050 |
| Compressor | DC inverter | DC inverter | DC inverter | DC inverter |
| Expansion device | Electronic expansion valve | Electronic expansion valve | Electronic expansion valve | Electronic expansion valve |
| Evaporator tubing | Internally grooved copper tube | Internally grooved copper tube | Internally grooved copper tube | Internally grooved copper tube |
| Fan quantity | 1 | 1 | 1 | 1 |
| External static pressure (Pa) | 0~150Pa | 0~150Pa | 0~150Pa | 0~150Pa |
| Fan type | EC fan | EC fan | EC fan | EC fan |
| Optional PTC electric heating capacity (kW) | 3 | 3 | 3 | 3 |
| Optional wet-film humidification capacity (kg/h) | 3 | 3 | 3 | 3 |
| Main power supply | 220V~/50Hz/1N | 380V~/50Hz/3N | 380V~/50Hz/3N | 380V~/50Hz/3N |
| Maximum distribution current (A) | 30 | 12 | 16 | 23 |
| Recommended circuit breaker | D32 | D16 | D25 | D32 |
| Main power input cable | 3×6 | 5×4 | 5×6 | 5×6 |
| Refrigerant | R410A | R410A | R410A | R410A |
| Parameter | FSA1008F/D (220V) | FSA1008F/D (380V) | FSA1013F/D | FSA1020F/D |
|---|---|---|---|---|
| Liquid pipe diameter (mm) | φ9.52 | φ9.52 | φ9.52 | φ12.7 |
| Gas pipe diameter (mm) | φ12.7 | φ12.7 | φ12.7 | φ16 |
| Humidifier water inlet connection (mm) | G1/2" | G1/2" | G1/2" | G1/2" |
| Condensate drain pipe diameter (mm) | 25 | 25 | 25 | 25 |
| Indoor/outdoor connecting cable | 3×1.5 | 3×1.5 | 3×1.5 | 4×1.5 |
| Parameter | FSA1008F/D (220V) | FSA1008F/D (380V) | FSA1013F/D | FSA1020F/D |
|---|---|---|---|---|
| Indoor dimensions, W × D × H (mm) | 660×555×1740 | 660×555×1740 | 660×555×1740 | 750×730×1900 |
| Outdoor dimensions, W × D × H (mm) | 960×390×810 | 960×390×810 | 960×390×1260 | 1070×990×1220 |
| Indoor gross weight (kg) | 123 | 123 | 125 | 190 |
| Outdoor gross weight (kg) | 38 | 38 | 58 | 75 |
| Parameter | FSA1008F/D (220V) | FSA1008F/D (380V) | FSA1013F/D | FSA1020F/D |
|---|---|---|---|---|
| Outdoor unit quantity | 1 | 1 | 1 | 1 |
| Outdoor fan type | Axial fan | Axial fan | Axial fan | Axial fan |
| Condenser tubing | Internally grooved copper tube | Internally grooved copper tube | Internally grooved copper tube | Internally grooved copper tube |