Product features
- DC inverter compressor, indoor EC variable-speed fan, electronic expansion valve and variable-speed condenser fan provide stepless cooling capacity control and 30% energy savings.
- Cooling close to the heat source, combined with hot/cold aisle containment, reduces airflow cooling losses and improves air delivery and cooling efficiency.
- Multiple fans operate at their optimum efficiency points and provide redundancy.
- Intelligent controls adjust fan speed to cooling demand, substantially reducing fan energy consumption.
- Cooling/heating and constant-temperature-and-humidity configurations meet different application requirements.
- Components from established brands provide high reliability, a design life exceeding ten years and low maintenance costs.
- A 7-inch touchscreen and multiple temperature and pressure sensors display unit operating status for operation and maintenance.
- High airflow and a small enthalpy difference meet equipment-room requirements for a high sensible heat ratio.
- Uses R410A refrigerant.
- Automatically restarts after power restoration and resumes the operating state used before the outage.
- Standard RS485 communication interface; a communication protocol can be supplied.
- Extensive self-diagnostics, alarms and protection functions support safe, reliable operation.
| Parameter | FRA1025F | FRA1035F | FRA1040F | FRA1050F | FRA1060F |
|---|---|---|---|---|---|
| Main power supply | 380V 3Ph-50Hz | 380V 3Ph-50Hz | 380V 3Ph-50Hz | 380V 3Ph-50Hz | 380V 3Ph-50Hz |
| Parameter | FRA1025F | FRA1035F | FRA1040F | FRA1050F | FRA1060F |
|---|---|---|---|---|---|
| Total cooling capacity (kW) | 25.0 | 35.0 | 42.0 | 50.0 | 60.0 |
| Sensible cooling capacity (kW) | 25.0 | 35.0 | 42.0 | 50.0 | 60.0 |
| Airflow (m³/h) | 5000 | 8000 | 9800 | 10500 | 12500 |
| Fan quantity | 6 | 3 | 3 | 3 | 3 |
| Compressor quantity | 1 | 1 | 1 | 1 | 1 |
| Parameter | FRA1025F | FRA1035F | FRA1040F | FRA1050F | FRA1060F |
|---|---|---|---|---|---|
| Heating capacity (kW) | 3 | 3 | 3 | 3 | 3 |
| Parameter | FRA1025F | FRA1035F | FRA1040F | FRA1050F | FRA1060F |
|---|---|---|---|---|---|
| Humidification capacity (kg/h) | 3 | 3 | 3 | 3 | 3 |
| Parameter | FRA1025F | FRA1035F | FRA1040F | FRA1050F | FRA1060F |
|---|---|---|---|---|---|
| Liquid pipe diameter (mm) | 12.7 | 16 | 19 | 19 | 19 |
| Gas pipe diameter (mm) | 16 | 22 | 22 | 22 | 22 |
| Humidifier water inlet (female thread) | G1/2" | G1/2" | G1/2" | G1/2" | G1/2" |
| Condensate pump drain inside diameter (mm) | 10 | 10 | 10 | 10 | 10 |
| Gravity drain inside diameter (mm) | 19 | 19 | 19 | 19 | 19 |
| Parameter | FRA1025F | FRA1035F | FRA1040F | FRA1050F | FRA1060F |
|---|---|---|---|---|---|
| Indoor dimensions, W × D × H (mm) | 300×1200×2000/2200 | 600×1200×2000/2200 | 600×1200×2000/2200 | 600×1200×2000/2200 | 600×1200×2000/2200 |
| Indoor weight (kg) | 225 | 260 | 270 | 318 | 318 |
| Outdoor dimensions, W × D × H (mm) | 1370×990×1220 | 1565×1275×1275 | 1565×1275×1275 | 1565×1275×1300 | 2065×1275×1275 |
| Outdoor weight (kg) | 85 | 135 | 140 | 145 | 240 |
| Parameter | FRA1025F | FRA1035F | FRA1040F | FRA1050F | FRA1060F |
|---|---|---|---|---|---|
| Maximum operating current, FLA (A) | 45 | 42 | 44 | 48 | 52 |
| Parameter | FRA1025F | FRA1035F | FRA1040F | FRA1050F | FRA1060F |
|---|---|---|---|---|---|
| Circuit breaker, cooling only (A) | 4P-32A | 4P-32A | 4P-32A | 4P-32A | 4P-32A |
| Cable specification, cooling only (mm²) | 3*4+2*2.5 | 3*4+2*2.5 | 3*4+2*2.5 | 3*4+2*2.5 | 3*4+2*2.5 |
| Circuit breaker, constant temperature and humidity (A) | 4P-50A | 4P-50A | 4P-50A | 4P-50A | 4P-63A |
| Cable specification, constant temperature and humidity (mm²) | 3*10+2*6 | 3*10+2*6 | 3*10+2*6 | 3*10+2*6 | 3*10+2*6 |
Applications
Data centers (IDC) · Telecommunications equipment rooms · Medium and large computer rooms · UPS and battery rooms · Industrial control rooms · Power distribution rooms · Transformer rooms · Precision equipment workplaces
Reference conditions & selection notes
- Air-cooled standard conditions: indoor return air dry-bulb temperature 35°C, wet-bulb temperature 21°C (27%RH); outdoor ambient dry-bulb temperature 35°C; external static pressure adjustable from 10 to 75Pa.
- An intelligent dual-cycle Refrigerant Pump system is optional.
- Outdoor unit specifications are matched to outdoor ambient temperature; flat or centralized outdoor units can be selected to suit the available footprint.
- Indoor unit depth can be customized to 1100mm or 1200mm.
- Heating, humidification and upward condensate drainage are optional to customer requirements.